DateAuthorLogOptionsExposure
2021-07-05WeiweiAiChange the figures size to fit the Physiome paper; Adjust the solver setting to remove the notch in Fig6. Minor editting in README. [files][create_exposure]
2021-06-28WeiweiAiSet interpolate solution to be False, which gives more accurate results for I_Na at around -65mV (i.e., eliminate the notch in Fig6) [files][create_exposure]
2021-06-21WeiweiAiCorrect the figure numbers in the doc and typos; Change the default temerature back to 310K for Periodic_stimulation. [files][create_exposure]
2021-06-21WeiweiAiAdd comments for paramater difference from difference sources in default_values.cellml Add T and Cao in the patch experiment to simulate fig 11; Add T in the periodic stimulation experiment; Add fig 10 and 11; Rerun the simulation and update the documentation. [files][create_exposure]
2021-06-09WeiweiAiUpdate figure titles and documentation; [files][create_exposure]
2021-06-09WeiweiAiAdd Fig 9 and 13. [files][create_exposure]
2021-06-09WeiweiAiAdd SA experiment and more documentation, figures [files][create_exposure]
2021-06-08WeiweiAiAdd readme [files][create_exposure]
2021-06-08WeiweiAioutput norm to confirm the values [files][create_exposure]
2021-06-08WeiweiAiModify tau_dCaT to 1.9508 and the parameter in phi_s (0.05956) to 0.005956 (Eq S-24) based on the C code; Add ICaL_channel_states_off and ICaL_off for Clamped_current_Xi to switch off the Cai dependency. [files][create_exposure]
2021-06-07WeiweiAiFixed the path errors /components..; Modify the parameters to comply with the ones that the author provided C code (https://computationalbiolab.github.io/jejunal_smc_model/) used. [files][create_exposure]
2021-06-03WeiweiAiAdd python scripts for simulation [files][create_exposure]
2021-06-03WeiweiAiImport Unit nM4 [files][create_exposure]
2021-06-03WeiweiAiFixed the different reference T0 for ICaL and ICaT; Add python scripts for Fig8 simulation and plot. There is a big error in Cai which needs further investigation [files][create_exposure]
2021-06-02WeiweiAiMove experiment parameters to *experiment.cellml; Add intracellular concentrations to the outputs; Add clamp protocol and experiments; Add the figures in the paper and digitalized data (not complete yet). [files][create_exposure]
2021-06-02WeiweiAiAdd E_Nernst to instantiate Nernst potential for Ca, Na and K and modify relevant models to accommodate the change. Add experiment of Periodic_stimulation, which can run. [files][create_exposure]
2021-06-01WeiweiAiAdd more components; Membrane_potential passed the validation with "[Warning] [128:38] Units validation results may be incorrect because the exponent is not a constant." [files][create_exposure]
2021-05-31WeiweiAiBasic components [files][create_exposure]